IH 35E

over Oak Lawn Ave & Turtle Ck

2.0 Mi N of IH 30, Dallas County, Texas

Condition

Poor

Year Built

1959

Daily Traffic

194,462

Length

133 ft

About This Bridge

IH 35E carries traffic over Oak Lawn Ave & Turtle Ck in Dallas County, Texas. Built in 1959, this structure is 67 years old, placing it among the older bridges still in active service. The bridge features prestressed concrete construction with a stringer/multi-beam or girder design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 194,462 vehicles cross this bridge daily, making it a high-traffic corridor critical to regional transportation. Bridges carrying this volume require enhanced inspection schedules and proactive maintenance programs. Commercial trucks account for 10% of all crossings. This proportion of commercial traffic is typical for this roadway classification and is factored into the bridge's design load ratings.

The bridge is currently rated in poor condition based on federal inspection criteria established by the Federal Highway Administration. It is classified as structurally deficient, meaning one or more components have received a rating of 4 or below on the 0-9 scale. This designation indicates significant deterioration that warrants attention, though the bridge remains safe for travel within its posted limits. Structurally deficient does not mean unsafe—rather, it signals that repairs or replacement should be prioritized in transportation planning. With a total length of 133 feet, this structure falls within the typical range requiring standard inspection procedures conducted by certified bridge inspectors.

Concrete bridges offer excellent durability and relatively low maintenance requirements. They resist corrosion well but can develop cracking over time, particularly in regions with freeze-thaw cycles or heavy use of deicing chemicals. Regular inspection focuses on detecting cracks, spalling, and reinforcement corrosion.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

Structurally Deficient

This bridge has one or more component ratings of 4 or below, indicating significant deterioration that requires attention. The bridge remains safe for travel but may have load restrictions.

4

Deck Condition

Poor

5

Superstructure

Fair

5

Substructure

Fair

6

Channel & Protection

Satisfactory

4

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

The deck rating of 4 indicates advanced deterioration affecting the driving surface.

For a structure built in 1959, the current condition reflects the cumulative effects of age, traffic, and environmental exposure. High traffic volumes on a bridge in fair or poor condition typically elevate its priority for rehabilitation or replacement in state transportation planning.

Bridge Details

Prestressed Concrete is the primary structural material, which influences maintenance requirements and expected lifespan. The stringer/multi-beam or girder design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to State Highway Agency.

Construction

Year Built1959
Year Reconstructed1983
MaterialPrestressed Concrete
Design TypeStringer/Multi-beam or Girder
OwnerState Highway Agency

Dimensions

Total Length133 ft (40.7 m)
Max Span6 ft (1.8 m)
Deck Width16 ft
Deck Area20,086 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 20,086 sq ft determines surface maintenance scope.

Classification

Route TypeInterstate
Route Number35
Lanes On Bridge10
Lanes Under Bridge11

Status

Toll BridgeNo
Historical SignificancePossibly eligible
Scour Critical6
Detour Length1 mi (2 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

194,462

Avg Daily Traffic (2020)

Vehicles per day crossing this bridge

10%

Truck Traffic

Commercial vehicle percentage

299,380

Projected Future ADT

Estimated future demand

This bridge carries approximately 194,462 vehicles per day, translating to roughly 70,978,630 crossings annually. This high volume places significant demands on the structure and necessitates frequent inspections.

Commercial trucks comprise 10% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces.

Traffic projections estimate future volumes of 299,380 vehicles daily, a 54% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

6.7 tons

Maximum allowable load for special permits

Inventory Rating

3.3 tons

Load level for normal traffic

The operating rating of 6.7 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 3.3 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Declining

Condition has declined by 1.0 rating points since 2020

Status Changes

  • Entered poor condition in 2021
  • Became structurally deficient in 2021

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

34.412500, -97.265833

Identification

Structure Number180570019603101
NBI IDTX-180570019603101
State FIPS48
County FIPS113

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.

This data is for informational purposes only and should not be used for route clearance or vehicle weight decisions.

IH 35E over Oak Lawn Ave & Turtle Ck | Texas