SPUR 557 EB CONN

over IH 20

0.95 MI E OF FM 148, Kaufman County, Texas

Condition

Fair

Year Built

1987

Daily Traffic

2,122

Length

63 ft

About This Bridge

SPUR 557 EB CONN carries traffic over IH 20 in Kaufman County, Texas. Built in 1987, this structure is 39 years old, built during a period of significant highway expansion. The bridge features prestressed concrete construction with a stringer/multi-beam or girder design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 2,122 vehicles cross this bridge daily, indicating lower traffic volumes common for local roads and rural routes. While traffic is lighter, these bridges still serve essential community transportation needs. Commercial trucks account for 21% of all crossings. This heavy commercial usage significantly impacts structural wear, as a single fully-loaded truck can cause as much deck wear as thousands of passenger vehicles. Transportation planners factor this into maintenance scheduling and budget allocation.

The bridge is currently rated in fair condition based on federal inspection criteria established by the Federal Highway Administration. The structure meets current safety standards for its designated use and load capacity. With a total length of 63 feet, this is a shorter span typical of local road crossings, often carrying traffic over small streams, drainage channels, or other roadways.

Concrete bridges offer excellent durability and relatively low maintenance requirements. They resist corrosion well but can develop cracking over time, particularly in regions with freeze-thaw cycles or heavy use of deicing chemicals. Regular inspection focuses on detecting cracks, spalling, and reinforcement corrosion.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

7

Deck Condition

Good

7

Superstructure

Good

6

Substructure

Satisfactory

Channel & Protection

N/A

6

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

The fair condition rating of 6 indicates satisfactory condition with minor section loss or deterioration.

For a structure built in 1987, this condition level is expected given the bridge's age and usage patterns.

Bridge Details

Prestressed Concrete is the primary structural material, which influences maintenance requirements and expected lifespan. The stringer/multi-beam or girder design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to State Highway Agency.

Construction

Year Built1987
MaterialPrestressed Concrete
Design TypeStringer/Multi-beam or Girder
OwnerState Highway Agency

Dimensions

Total Length63 ft (19.1 m)
Max Span13 ft (4.0 m)
Deck Width4 ft
Deck Area2,335 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 2,335 sq ft determines surface maintenance scope.

Classification

Route TypeState Highway
Route Number557
Lanes On Bridge1
Lanes Under Bridge4

Status

Toll BridgeNo
Historical SignificanceNot eligible
Scour CriticalN
Detour Length1 mi (2 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

2,122

Avg Daily Traffic (2016)

Vehicles per day crossing this bridge

21%

Truck Traffic

Commercial vehicle percentage

3,160

Projected Future ADT

Estimated future demand

This bridge carries approximately 2,122 vehicles per day, translating to roughly 774,530 crossings annually. Lower traffic volumes generally result in less structural wear over time.

Commercial trucks comprise 21% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces. This high percentage of truck traffic may accelerate deterioration of deck surfaces and structural components.

Traffic projections estimate future volumes of 3,160 vehicles daily, a 49% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

5.4 tons

Maximum allowable load for special permits

Inventory Rating

3.3 tons

Load level for normal traffic

The operating rating of 5.4 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 3.3 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Stable

Condition has remained relatively stable since 2020

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

34.189444, -97.377500

Identification

Structure Number181300009514381
NBI IDTX-181300009514381
State FIPS48
County FIPS257

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.

This data is for informational purposes only and should not be used for route clearance or vehicle weight decisions.

SPUR 557 EB CONN over IH 20 | Texas