GREENLAWN AVE

over SCIOTO RIVER (GREENLAWN)

0.2 MI WEST OF HIGH ST, Franklin County, Ohio

Condition

Good

Year Built

1974

Daily Traffic

5,212

Length

84 ft

About This Bridge

GREENLAWN AVE carries traffic over SCIOTO RIVER (GREENLAWN) in Franklin County, Ohio. Built in 1974, this structure is 52 years old, placing it among the older bridges still in active service. The bridge features steel continuous construction with a stringer/multi-beam or girder design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 5,212 vehicles cross this bridge daily, indicating lower traffic volumes common for local roads and rural routes. While traffic is lighter, these bridges still serve essential community transportation needs. Commercial trucks account for 7% of all crossings. This proportion of commercial traffic is typical for this roadway classification and is factored into the bridge's design load ratings.

The bridge is currently rated in good condition based on federal inspection criteria established by the Federal Highway Administration. The structure meets current safety standards for its designated use and load capacity. With a total length of 84 feet, this is a shorter span typical of local road crossings, often carrying traffic over small streams, drainage channels, or other roadways.

The construction materials used in this bridge were selected based on engineering requirements, cost considerations, and local conditions at the time of construction.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

8

Deck Condition

Very Good

7

Superstructure

Good

7

Substructure

Good

8

Channel & Protection

Very Good

7

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

With a lowest rating of 7, this bridge demonstrates good condition meeting all safety standards.

For a structure built in 1974, maintaining good condition demonstrates effective maintenance practices.

Bridge Details

Steel Continuous is the primary structural material, which influences maintenance requirements and expected lifespan. The stringer/multi-beam or girder design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to County Highway Agency.

Construction

Year Built1974
Year Reconstructed2007
MaterialSteel Continuous
Design TypeStringer/Multi-beam or Girder
OwnerCounty Highway Agency

Dimensions

Total Length84 ft (25.5 m)
Max Span13 ft (3.8 m)
Deck Width8 ft
Deck Area5,937 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 5,937 sq ft determines surface maintenance scope.

Classification

Route TypeCity Street
Route Number146
Lanes On Bridge4
Lanes Under Bridge

Status

Toll BridgeNo
Historical SignificanceNot eligible
Scour CriticalNo
Detour Length4 mi (6 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

5,212

Avg Daily Traffic (2015)

Vehicles per day crossing this bridge

7%

Truck Traffic

Commercial vehicle percentage

7,234

Projected Future ADT

Estimated future demand

This bridge carries approximately 5,212 vehicles per day, translating to roughly 1,902,380 crossings annually. Lower traffic volumes generally result in less structural wear over time.

Commercial trucks comprise 7% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces.

Traffic projections estimate future volumes of 7,234 vehicles daily, a 39% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

7.1 tons

Maximum allowable load for special permits

Inventory Rating

4.2 tons

Load level for normal traffic

The operating rating of 7.1 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 4.2 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Stable

Condition has remained relatively stable since 2020

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

40.546944, -83.103056

Identification

Structure Number2531755
NBI IDOH-2531755
State FIPS39
County FIPS049

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.