XTOWN (SR-618) WB

over CSX RAILROAD AND 26TH ST

22ND STREET OFF-RAMP WB, Hillsborough County, Florida

Condition

Good

Year Built

2013

Daily Traffic

4,900

Length

172 ft

About This Bridge

XTOWN (SR-618) WB carries traffic over CSX RAILROAD AND 26TH ST in Hillsborough County, Florida. Built in 2013, this structure is 13 years old, representing modern engineering and construction standards. The bridge features prestressed concrete continuous construction with a segmental box girder design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 4,900 vehicles cross this bridge daily, indicating lower traffic volumes common for local roads and rural routes. While traffic is lighter, these bridges still serve essential community transportation needs. Commercial trucks account for 10% of all crossings. This proportion of commercial traffic is typical for this roadway classification and is factored into the bridge's design load ratings.

The bridge is currently rated in good condition based on federal inspection criteria established by the Federal Highway Administration. The structure meets current safety standards for its designated use and load capacity. With a total length of 172 feet, this structure falls within the typical range requiring standard inspection procedures conducted by certified bridge inspectors.

The construction materials used in this bridge were selected based on engineering requirements, cost considerations, and local conditions at the time of construction.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

8

Deck Condition

Very Good

8

Superstructure

Very Good

8

Substructure

Very Good

Channel & Protection

N/A

8

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

With a lowest rating of 8, this bridge demonstrates very good condition with only minor issues.

For a structure built in 2013, maintaining good condition demonstrates effective maintenance practices.

Bridge Details

Prestressed Concrete Continuous is the primary structural material, which influences maintenance requirements and expected lifespan. The segmental box girder design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to State Toll Authority.

Construction

Year Built2013
MaterialPrestressed Concrete Continuous
Design TypeSegmental Box Girder
OwnerState Toll Authority

Dimensions

Total Length172 ft (52.3 m)
Max Span25 ft (7.7 m)
Deck Width4 ft
Deck Area6,850 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 6,850 sq ft determines surface maintenance scope.

Classification

Route TypeOther
Route Number618
Lanes On Bridge2
Lanes Under Bridge2

Status

Toll BridgeYes
Historical SignificanceNot eligible
Scour CriticalN
Detour Length2 mi (3 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

4,900

Avg Daily Traffic (2024)

Vehicles per day crossing this bridge

10%

Truck Traffic

Commercial vehicle percentage

6,125

Projected Future ADT

Estimated future demand

This bridge carries approximately 4,900 vehicles per day, translating to roughly 1,788,500 crossings annually. Lower traffic volumes generally result in less structural wear over time.

Commercial trucks comprise 10% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces.

Traffic projections estimate future volumes of 6,125 vehicles daily, a 25% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

4.6 tons

Maximum allowable load for special permits

Inventory Rating

3.5 tons

Load level for normal traffic

The operating rating of 4.6 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 3.5 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Stable

Condition has remained relatively stable since 2020

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

28.156111, -83.818889

Identification

Structure Number100694
NBI IDFL-100694
State FIPS12
County FIPS057

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.

This data is for informational purposes only and should not be used for route clearance or vehicle weight decisions.

XTOWN (SR-618) WB over CSX RAILROAD AND 26TH ST | Florida