MAIN ST

over VENTURA RIVER

0.5 MI W OF VENTURA AVE, Ventura County, California

Condition

Poor

Year Built

1932

Daily Traffic

6,853

Length

123 ft

About This Bridge

MAIN ST carries traffic over VENTURA RIVER in Ventura County, California. Built in 1932, this structure is 94 years old, making it a historic structure that has served the community for generations. The bridge features concrete construction with a tee beam design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 6,853 vehicles cross this bridge daily, indicating lower traffic volumes common for local roads and rural routes. While traffic is lighter, these bridges still serve essential community transportation needs. Commercial trucks account for 3% of all crossings. This proportion of commercial traffic is typical for this roadway classification and is factored into the bridge's design load ratings.

The bridge is currently rated in poor condition based on federal inspection criteria established by the Federal Highway Administration. It is classified as structurally deficient, meaning one or more components have received a rating of 4 or below on the 0-9 scale. This designation indicates significant deterioration that warrants attention, though the bridge remains safe for travel within its posted limits. Structurally deficient does not mean unsafe—rather, it signals that repairs or replacement should be prioritized in transportation planning. With a total length of 123 feet, this structure falls within the typical range requiring standard inspection procedures conducted by certified bridge inspectors.

Concrete bridges offer excellent durability and relatively low maintenance requirements. They resist corrosion well but can develop cracking over time, particularly in regions with freeze-thaw cycles or heavy use of deicing chemicals. Regular inspection focuses on detecting cracks, spalling, and reinforcement corrosion.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

Structurally Deficient

This bridge has one or more component ratings of 4 or below, indicating significant deterioration that requires attention. The bridge remains safe for travel but may have load restrictions.

7

Deck Condition

Good

7

Superstructure

Good

2

Substructure

Critical

5

Channel & Protection

Fair

2

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

The substructure rating of 2 reflects critical foundation or pier problems.

For a structure built in 1932, the current condition reflects the cumulative effects of age, traffic, and environmental exposure.

Bridge Details

Concrete is the primary structural material, which influences maintenance requirements and expected lifespan. The tee beam design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to City/Municipal.

Construction

Year Built1932
Year Reconstructed1979
MaterialConcrete
Design TypeTee Beam
OwnerCity/Municipal

Dimensions

Total Length123 ft (37.6 m)
Max Span6 ft (1.9 m)
Deck Width6 ft
Deck Area6,351 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 6,351 sq ft determines surface maintenance scope.

Classification

Route TypeCity Street
Route Number0
Lanes On Bridge2
Lanes Under Bridge

Status

Toll BridgeNo
Historical SignificanceNot eligible
Scour Critical2
Detour Length1 mi (2 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

6,853

Avg Daily Traffic (2019)

Vehicles per day crossing this bridge

3%

Truck Traffic

Commercial vehicle percentage

7,411

Projected Future ADT

Estimated future demand

This bridge carries approximately 6,853 vehicles per day, translating to roughly 2,501,345 crossings annually. Lower traffic volumes generally result in less structural wear over time.

Commercial trucks comprise 3% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces.

Traffic projections estimate future volumes of 7,411 vehicles daily, a 8% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

9.1 tons

Maximum allowable load for special permits

Inventory Rating

5.5 tons

Load level for normal traffic

The operating rating of 9.1 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 5.5 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Stable

Condition has remained relatively stable since 2020

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

35.818333, -120.361944

Identification

Structure Number52C0061
NBI IDCA-52C0061
State FIPS06
County FIPS111

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.

This data is for informational purposes only and should not be used for route clearance or vehicle weight decisions.

MAIN ST over VENTURA RIVER | California