E92-N880 CONNECTR

over I 880 S880-E92 CONNECTR

04-ALA-092-6.27-HAY, Alameda County, California

Condition

Fair

Year Built

2009

Daily Traffic

106,000

Length

81 ft

About This Bridge

E92-N880 CONNECTR carries traffic over I 880 S880-E92 CONNECTR in Alameda County, California. Built in 2009, this structure is 17 years old, representing modern engineering and construction standards. The bridge features prestressed concrete continuous construction with a box beam - multiple design, a combination chosen by engineers to meet the specific requirements of this crossing.

Approximately 106,000 vehicles cross this bridge daily, making it a high-traffic corridor critical to regional transportation. Bridges carrying this volume require enhanced inspection schedules and proactive maintenance programs. Commercial trucks account for 7% of all crossings. This proportion of commercial traffic is typical for this roadway classification and is factored into the bridge's design load ratings.

The bridge is currently rated in fair condition based on federal inspection criteria established by the Federal Highway Administration. The structure meets current safety standards for its designated use and load capacity. With a total length of 81 feet, this is a shorter span typical of local road crossings, often carrying traffic over small streams, drainage channels, or other roadways.

The construction materials used in this bridge were selected based on engineering requirements, cost considerations, and local conditions at the time of construction.

Federal law requires that all highway bridges be inspected at least every 24 months by qualified inspectors following the National Bridge Inspection Standards (NBIS). Some bridges with known issues or unusual characteristics may be inspected more frequently. Inspection data is reported to the National Bridge Inventory, a database maintained by the Federal Highway Administration that tracks the condition of all public highway bridges in the United States. This bridge data is sourced from that federal database and reflects the most recent available inspection results.

Condition Ratings

6

Deck Condition

Satisfactory

7

Superstructure

Good

7

Substructure

Good

Channel & Protection

N/A

6

Lowest Rating

Determines condition category

NBI condition ratings range from 0 (failed) to 9 (excellent). Ratings of 4 or below are considered poor. The overall condition category is determined by the lowest individual component rating.

The fair condition rating of 6 indicates satisfactory condition with minor section loss or deterioration.

For a structure built in 2009, this condition level is expected given the bridge's age and usage patterns.

Bridge Details

Prestressed Concrete Continuous is the primary structural material, which influences maintenance requirements and expected lifespan. The box beam - multiple design was selected based on span requirements, load capacity needs, and site conditions at the time of construction. Maintenance responsibility falls to State Highway Agency.

Construction

Year Built2009
MaterialPrestressed Concrete Continuous
Design TypeBox Beam - Multiple
OwnerState Highway Agency

Dimensions

Total Length81 ft (24.8 m)
Max Span15 ft (4.7 m)
Deck Width9 ft
Deck Area6,894 sq ft

Span dimensions affect structural design choices and load distribution. The deck area of 6,894 sq ft determines surface maintenance scope.

Classification

Route TypeState Highway
Route Number92
Lanes On Bridge3
Lanes Under Bridge10

Status

Toll BridgeNo
Historical SignificanceNot eligible
Scour CriticalN
Detour Length1 mi (1 km)

Traffic Data

Traffic volume data helps engineers assess bridge wear patterns and plan maintenance schedules. Average Daily Traffic (ADT) counts are updated periodically and represent typical weekday usage.

106,000

Avg Daily Traffic (2009)

Vehicles per day crossing this bridge

7%

Truck Traffic

Commercial vehicle percentage

161,932

Projected Future ADT

Estimated future demand

This bridge carries approximately 106,000 vehicles per day, translating to roughly 38,690,000 crossings annually. This high volume places significant demands on the structure and necessitates frequent inspections.

Commercial trucks comprise 7% of traffic. Heavy vehicles cause disproportionate wear—a single fully loaded truck can have the impact of thousands of passenger cars on bridge deck surfaces.

Traffic projections estimate future volumes of 161,932 vehicles daily, a 53% increase from current levels. These projections inform capacity planning and potential upgrade requirements.

Load Ratings

Load ratings determine what weight this bridge can safely support. These values are critical for routing heavy vehicles and issuing overweight permits.

Operating Rating

5.4 tons

Maximum allowable load for special permits

Inventory Rating

3.2 tons

Load level for normal traffic

The operating rating of 5.4 tons represents the absolute maximum load this bridge can carry under controlled conditions with special permits. The inventory rating of 3.2 tons is the safe load limit for everyday traffic without restrictions. These relatively low ratings may result in posted weight limits or route restrictions for heavy vehicles.

5-Year Condition Trend

Declining

Condition has declined by 1.0 rating points since 2020

Data: 2020-2024 FHWA National Bridge Inventory

Location

Loading map...

38.565000, -123.166667

Identification

Structure Number33 0679G
NBI IDCA-33 0679G
State FIPS06
County FIPS001

Explore More

Data Source: Federal Highway Administration (FHWA) National Bridge Inventory 2024

Bridge inspection data is typically updated every 24 months. Conditions may have changed since the last inspection.

“Structurally deficient” does not mean a bridge is unsafe or likely to collapse. It indicates that one or more key structural elements are in poor or worse condition. Bridges are inspected regularly and may have load restrictions in place.

This data is for informational purposes only and should not be used for route clearance or vehicle weight decisions.

E92-N880 CONNECTR over I 880 S880-E92 CONNECTR | California